Producing reliable power of 50 ekW at 60 Hz, our D50 GC diesel generator sets designed to ISO 8528-5 transient response requirements. All D50 GC generator sets meet EPA Stationary Emergency (Tier 3) emissions standards.
Get a Quote
Benefits
Saves up to 22% Installed Space
Requires less space for installation; leaves more room for your on-going operations
Reliability tested for 500 Hours
Ensures you can count on emergency power when it is needed
Spare Parts 98% Fulfillment within 24 hours
World's best product support network ensures spare parts are readily available for maintenance and service needs
Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
Fuel System
Standard open set fuel tank/base supplied base, formed steel with single wall integral 24-hour fuel tank
Cooling System
Fan drive, battery charging alternator drive
Caterpillar extended life coolant
Radiator and cooling fan with guards
Coolant drain line with valve
Radiator stone guard
Control Panels
NFPA110 bundle includes:
WCA1 Low coolant temperature alarm
FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected
WSS1 Low coolant level shut down
PBC10NU NFPA battery charger
Oil temperature gauge and sender
PAA1 Panel mounted audible alarm
A Coolant heater, remote annunciator or 0.8 power factor test may be required depending on the application
Audible alarm
Remote E-stop button
Ground fault relay
Discrete I/O module
Remote annunciator module
Volt free contacts genset run and common alarm
Fuel level reading
Protective devices:
Low coolant temperature alarm
Low coolant level shutdown
Overload shutdown via breaker
Generator
12 Leads
Governing System
Mechanical and electrical governing system - model dependent
Lube System
Lubricating oil
Oil drain line with valve
General
Engine and alternator pre-paint, Caterpillar yellow
Starting/Charging System
Batteries
24V battery with rack and cables
Certificates
IBC seismic and wind Certifications
Air Inlet System
Cartridge type air filter
Alternator System
R Frame auxilliary winding
Charging System
NFPA battery charger UL10A 120VAC
Circuit breakers
Breakers (100% UL rated)
Power terminal strip
3-Pole 100% rated
Second circuit breaker box
Control Panels
Volt free contacts genset run and common alarm
Oil temperature gauge and sender
Remote E-stop button
Protective devices: Low coolant temperature alarm - Low coolant level shutdown - Fuel level reading - Overload shutdown via breaker
Audible alarm
Remote annunciator module
Discrete I/O module
NFPA110 bundle includes: FSS Low fuel level alarm & indication panel circuitry required
when sub-base tank is selected - WSS1 Low coolant level shut down - WCA1 Low coolant temperature alarm - PAA1 Panel mounted audible alarm - PBC10NU NFPA battery charger - A Coolant heater ,remote annunciator or 0.8 power factor test may be required depending on the application