350 ekW Diesel Generator Set

The D350 GC diesel generator sets have been developed to meet your needs in standby applications. Producing reliable power of 350 ekW at 60 Hz, each generator set has been designed to meet ISO 8528-5 transient response requirements and built to accept 100 % rated load in one step. Our D350 GC generator sets are engineered to EPA Stationary Emergency (Tier 3) emissions standards.

Get a Quote

    Fabick Cat needs this information to contact you about our products and services. You may unsubscribe from communications at any time. For more information, please review our Privacy Policy.

    Benefits

    Saves up to 33% Installed Space

    Requires less space for installation; leaves more room for your on-going operations

    Weighs up to 19% Less

    Easier handling; less structural reinforcement required to support genset weight

    Standard 105°C Alternator Temperature Rise

    Meets most all specifications; ensures long alternator life
    • Engine Specifications
      Aspiration
      Turbocharged Air-to-Air Aftercooled
      Bore
      5.1 in
      Compression Ratio
      16.3:1
      Displacement
      763 in³
      Engine Model
      Cat® C13 In-line 6, 4-cycle diesel
      Fuel System
      MEUI
      Governor Type
      ADEMA4
      Stroke
      6.2 in
    • Generator Set Dimensions
      Dry Weight - Genset (maximum)
      7255.4 lb
      Dry Weight - Genset (minimum)
      6929.1 lb
      Height - Maximum
      96.7 in
      Height - Minimum
      80.3 in
      Length - Maximum
      182.8 in
      Width - Maximum
      64.2 in
    • Generator Set Specifications
      Duty Cycle
      Standby
      Emissions/Fuel Strategy
      EPA Stationary Emergency
      Frequency
      60 Hz
      Maximum Rating
      350 ekW
      Minimum Rating
      350 ekW
      Speed
      1800 rpm
      Voltage
      480 to 600 Volts
    Air Inlet System
    • Turbocharger
    • Aftercooler core
    • Air cleaner - Non canister, disposable
    Control Panel
    • GCCP 1.2
    Cooling System
    • Radiator sight gauge
    • Blower fan and fan drive with guards
    • Radiator, package mounted
    • Coolant drain valve
    • Thermostats and housing
    • Jacket water pump, gear driven, centrifugal
    Exhaust System
    • Exhaust manifold - dry
    Fuel System
    • Integral tank base, 24 hours, UL142
    • Engine fuel transfer pump
    • Primary fuel filter w/integral water separator and secondary filter, spin on
    • Fuel cooler
    • Fuel priming pump
    Generator Set
    • Complete system designed & built at ISO 9001:2000 certified facilities
    • All protective devices and control functions simulated and checked
    • Factory tested to design specifications at full load conditions
    Generators and Generator Attachments
    • 6 Leads
    • Brushless, self-excited 2/3 pitch (600V uses Internal excitation (IE))
    • Terminal box, IP22 RHS facing, bottom cable entry
    • Standard winding protection for non-harsh environments with relative humidity ? 95%
    • IP23 Protection
    • Voltage regulator (single phase sensing)
    • Easy access to AVR and terminals
    • Insulation system, Class H
    Governing System
    • Cat electronic governor (ADEM A4)
    Lube System
    • Oil drain with valve
    • Lubricating oil, CK-4 (10W-30)
    • Oil filter, spin on
    • Oil cooler
    • Oil filler and dipstick
    • Fumes disposal to front of radiator
    • Shallow oil pan
    Mounting System
    • Captive linear vibration isolators between base and engine-generator
    • Includes lifting provisions and termination points for coolant and lube oil drain lines
    Protection
    • Safety shutoff - High water temperature
    • Safety shutoff - Low oil pressure
    • Safety shutoff - Overspeed
    Starting/Charging System
    • 24-volt electric starting motor
    • 24V, 45 Amp Charging alternator
    General
    • Vibration damper
    • Parts book
    • Lifting eyes
    Air Inlet System
    • Air cleaner (Non canister disposable)
    Bases, Mounting & Fuel Tanks
    • Wide Base - Skid
    • Overfill prevention valve
    • 5 Gallon Spill Containment
    • Fuel tank pill pipe & lockable cap
    • Integral tank base, 24 hours, UL142
    • Audio & visual fuel alarm (@90% fuel level)
    Circuit breaker
    • 1200A LS/I
    • 800A LSI
    • 400A LS/I
    • Auxiliary contacts
    • 600A LS/I
    • 600A LSI
    • 1200A LSI
    • 400A LSI
    • 800A LS/I
    Control System
    • Volt free contacts
    • Ground fault relay
    • Audible alarm Gp
    • Twist release, Red button emergency stop
    • 20A GFCI (Ground Fault Circuit Interrupter)
    • 100A Load center
    • Product link remote monitoring hardware
    • 16 -light NFPA 99/110 Annunciator
    Enclosures
    • E-Stop
    • Sound attenuated Level 2 enclosure (White)
    • AC & DC Source lights
    Exhaust System
    • Flexible exhaust connection
    • 8" Muffler - 25 dBA attenuation
    • Manifold and turbocharger guards
    Generator
    • Space heater
    • Permanent magnet excitation (PMG) generator
    Starting System
    • Battery charger (UL Certified)
    • Jacket water heater
    • Standard battery set: 1000 CCA, 90 amp/hr.
    • Oversize battery set, 1400 CCA, 200 amp/hr
    Circuit breakers
    • Circuit breaker (IEC) Auxiliary contacts
    • 4 Pole (IEC-100% rated) Circuit breaker - Motorised
    • Shunt trip for IEC circuit breaker
    General
    • Extended Service Coverage
    • UL2200 Certification
    • CSA Certification
    • Generator test report
    starting / Charging System
    • Jacket water heater
    • Battery disconnect switch