New CAT Equipment

D300 GC (60 Hz) Generator Set

300 ekW Diesel Generator Set

Producing reliable power of 300 ekW at 60 Hz, our D300 GC diesel generator set are designed to ISO 8528-5 transient response requirements. The D300 GC generator sets are engineered to EPA Stationary Emergency (Tier 3) emissions standards.

Get a Quote

Benefits

Saves up to 31% Installed Space

Requires less space for installation; leaves more room for your on-going operations

Weighs up to 26% Less

Easier handling; less structural reinforcement required to support genset weight

Standard 105°C Alternator Temperature Rise

Meets most all specifications; ensures long alternator life
  • Engine Specifications
    Aspiration
    Turbocharged Air-to-Air Aftercooled
    Bore
    4.4 in
    Compression Ratio
    16.3:1
    Displacement
    538 in³
    Engine Model
    Cat® C9 In-line 6, 4-cycle diesel
    Fuel System
    HEUI
    Governor Type
    AdemA4
    Stroke
    5.9 in
  • Generator Set Dimensions
    Dry Weight - Genset (maximum)
    6929.1 lb
    Dry Weight - Genset (minimum)
    5518.2 lb
    Height - Maximum
    86.7 in
    Height - Minimum
    67.2 in
    Length - Maximum
    155.5 in
    Width - Maximum
    56.7 in
    Width - Minimum
    56.3 in
  • Generator Set Specifications
    Duty Cycle
    Standby
    Emissions/Fuel Strategy
    EPA Stationary Emergency
    Frequency
    60 Hz
    Maximum Rating
    300 ekW
    Minimum Rating
    300 ekW
    Speed
    1800 rpm
    Voltage
    208 to 600 Volts
Air Inlet System
  • Aftercooler core
  • Turbocharger
  • Air cleaner - Non canister, disposable
Control Panel
  • GCCP 1.2
Cooling System
  • Jacket water pump, gear driven, centrifugal
  • Thermostats and housing
  • Coolant drain valve
  • Radiator sight gauge
  • Blower fan and fan drive with guards
  • Radiator, package mounted
Exhaust System
  • Exhaust manifold - dry
Fuel System
  • Integral tank base, 24 hours, UL142
  • Fuel priming pump
  • Engine fuel transfer pump
  • Primary fuel filter w/integral water separator and secondary filter, spin on
Generator Set
  • Complete system designed & built at ISO 9001:2000 certified facilities
  • All protective devices and control functions simulated and checked
  • Factory tested to design specifications at full load conditions
Generators and Generator Attachments
  • IP23 Protection
  • 12 Leads
  • Insulation system, Class H
  • Standard winding protection for non-harsh environments with relative humidity ? 95%
  • Voltage regulator (single phase sensing)
  • Easy access to AVR and terminals
  • Terminal box, IP22 RHS facing, bottom cable entry
  • Brushless, self-excited 2/3 pitch (600V uses Internal excitation (IE))
Governing System
  • Cat electronic governor (ADEM A4)
Lube System
  • Shallow oil pan
  • Oil cooler
  • Fumes disposal to front of radiator
  • Oil drain with valve
  • Oil filler and dipstick
  • Oil filter, spin on
  • Lubricating oil, CK-4 (10W-30)
Mounting System
  • Captive linear vibration isolators between base and engine-generator
  • Includes lifting provisions and termination points for coolant and lube oil drain lines
Protection
  • Safety shutoff - High water temperature
  • Safety shutoff - Low oil pressure
  • Safety shutoff - Overspeed
Starting/Charging System
  • 24-volt electric starting motor
  • 24V, 45 Amp Charging alternator
General
  • Lifting eyes
  • Vibration damper
  • Parts book
Air Inlet System
  • Air cleaner (Non canister disposable)
Bases, Mounting & Fuel Tanks
  • Integral tank base, 24 hours, UL142
  • Audio & visual fuel alarm (@90% fuel level)
  • Wide Base - Skid
  • Fuel tank pill pipe & lockable cap
Circuit breaker
  • 400A LSI
  • 600A LSI
  • 1200A LSI
  • 800A LS/I
  • Auxiliary contacts
  • 600A LS/I
  • 1200A LS/I
  • 400A LS/I
  • 800A LSI
Control System
  • Audible alarm Gp
  • 16 -light NFPA 99/110 Annunciator
  • Twist release, Red button emergency stop
  • Ground fault relay
  • 100A Load center
  • Product link remote monitoring hardware
  • 20A GFCI (Ground Fault Circuit Interrupter)
  • Volt free contacts
Enclosures
  • Sound attenuated Level 2 enclosure (White)
  • AC & DC Source lights
  • E-Stop
Exhaust System
  • 6" Muffler - 25 dBA attenuation
  • Manifold and turbocharger guards
  • Flexible exhaust connection
Generator
  • Space heater
  • Permanent magnet excitation (PMG) generator
Starting System
  • Battery charger (UL Certified)
  • Jacket water heater
  • Standard battery set: 1000 CCA, 90 amp/hr.
General
  • CSA Certification
  • Extended Service Coverage
  • UL2200 Certification
  • Generator test report