New CAT Equipment

D200 GC Generator Set

200 ekW Diesel Generator Set

Producing reliable power of 200 ekW at 60 Hz, our Cat® C7.1 D200 GC diesel generator set is designed to meet ISO 8528-5 transient response requirements and U.S. EPA emission norms.

Get a Quote

Benefits

Saves up to 18% Installed Space

Requires less space for installation; leaves more room for your on-going operations

Reliability tested for 500 Hours

Ensures you can count on emergency power when it is needed

Spare Parts 98% Fulfillment within 24 hours

World's best product support network ensures spare parts are readily available for maintenance and service needs
  • Engine Specifications
    Aspiration
    Turbocharged, Air to Air Aftercooled
    Bore
    4.1 in
    Compression Ratio
    16.7:1
    Displacement
    428 in³
    Engine Model
    C7.1 I-6, 4-Cycle Diesel
    Fuel System
    Electronic, Common Rail
    Governor Type
    ADEM™A4
    Stroke
    5.31 in
  • Generator Set Dimensions
    Dry Weight - Genset (maximum)
    3917 lb
    Height - Maximum
    58.7 in
    Length - Maximum
    103.7 in
    Width - Maximum
    51.2 in
  • Generator Set Specifications
    Duty Cycle
    Standby
    Emissions/Fuel Strategy
    U.S. EPA Tier 3 Certified
    Frequency
    60 Hz
    Speed
    1800 rpm
    Standby Rating
    200 ekW
    Voltage
    208 to 600 Volts
Air Inlet System
  • Air cleaner; light duty with disposable element
Control Panels
  • GCCP 1.2
Cooling System
  • Coolant drain line with valves
  • Radiator and cooling fan with guards
  • Caterpillar extended life coolant
  • Fan drive, battery charging alternator drive
Fuel System
  • Standard open set fuel tank wide base
Lube System
  • Oil drain line with valve
  • Lubricating oil
Mounting System
  • Captive linear vibration isolators
  • Includes lifting provision and drag points
  • Termination points for coolant and lube oil drain lines
Starting / Charging System
  • 24V battery with rack and cables
Governing System
  • Cat electronic governor ADEM A4
General
  • Engine and alternator pre-paint, Caterpillar yellow
Telematics
  • Cat® Product Link™ PL444 cellular
Alternator System
  • Battery disconnect switch
  • SE, AREP, PMG Excitation
  • Anti-condensation heater
  • Mounting & Duct plate
Circuit breakers
  • Single / Multi manual circuit breakers
Exhaust System
  • 10,25,35 dBA mufflers / Enclosure muffler
Control Panel Options
  • Panel mounted audible alarm
  • NFPA 110 bundle
  • Emergency stop with key
  • Earth fault (2 wire only)
  • I/O Expansion module
Control System
  • Current transformer
  • Volt free contacts for common alarm
  • Static battery charger
Cooling System
  • Low coolant temperature
  • Jacket water heater
  • Low coolant level shutdown
Enclosures
  • Sound attenuated level 2 enclosure
Fuel Systems
  • 24 hrs integral fuel tank
  • Low fuel level alarm
  • Fuel vent pipe / Vent pipe extention
  • High fuel level alarm
General
  • Stone guards/radiator trans flange
Certifications
  • IBC Seismic, UL2200
Power Termination
  • Circuit breaker, Neutral bars, Shunt trips