Cat® CBS Series

The CBS Series – Open Transition, Delayed Transition (CBSD), Closed Transition (CBSCT), ATS with Bypass Isolationis is equipped with an intuitive full-color touchscreen HMI and is compatible with Ekip Connect software for commissioning and operation.

The CBS Series has an array of standard programmable functions and is built for high performance and service with proactive outage mitigation that monitors temperature and contact health. Fast switching and no line voltages connected at the door provide advanced safety.

Get a Quote

    Fabick Cat needs this information to contact you about our products and services. You may unsubscribe from communications at any time. For more information, please review our Privacy Policy.

    Benefits

    HMI unit, type CBS color touchscreen with Ekip Programming module

    Contact wear monitoring including real-time status and predicted contact end-of-life

    Advanced safety with fast switching (<50ms) and no line voltages connected at the door

    • System Information
      Neutral configuration
      Solid neutral, Switched neutral, Overlapping neutral (100-1200A only)
      Number of poles
      2, 3 and 4
      Phase system
      Single and Three
      Product nodes
      UL: Open transition 100-3000A, Delayed transition 100-3000A, Closed transition 1000-3000A
      Product type
      Open transition (I-II), Delayed Transition (I-O-II), Closed transition (I-O-II)
      Rated Voltage and Frequency
      200-480VAC, 50/60 Hz
    • Technical Summary
      Rating Range
      100 - 3000 A
      Switch Type
      Contactor
      Transfer Type
      Open Transition (CBS), Delayed Transition (CBSD), Closed Transition (CBSCT), with Bypass Isolation
    Control
    • Color touchscreen
    • Voltage and frequency settings: Pick up and Drop out
    • Time Delay Settings: Override momentary, Transfer, Generator stop, Center-OFF (Delayed Transition Type), Pre-transfer, Post-transfer, Elevator Pre-signal, Elevator Post-signal, and Load shead.
    • Source failure detections: No Voltage, Under/Over Voltage, Phase missing, Voltage unbalance, Invalid frequency, and Incorrect phase sequence
    Additional Features
    • LED indications for ATS, S1 and S2 status
    • Programmable digital inputs/outputs
    • Auto config (voltage, frequency, phase system)
    • Source priority (Source 1/2, No priority)
    • Manual re-transfer
    • In-phase monitor (synchro check)
    • Genset exercising: on-load, off-load
    • In-built power meter module
    • Load shedding
    • Real time clock
    • Event log
    • Predictive maintenance
    • Voltage and current harmonics measuring
    Accessories
    • Auxiliary contacts for position indication
    • Digital input/output modules (factory programmed)
    • 12-24 VDC aux supply module for controller
    • Communication modules
    Connectivity Capability
    • Modbus RTU (RS-485)
    • Modbus/TCP
    • Profibus DP
    • ProfiNet Yes
    • DeviceNet
    • Ethernet IP
    Applications
    • Utility - Utility
    • Utility - Generator
    UL short circuit withstand ratings
    • Coordinated breaker WCR
    • Time-based WCR
    • Short-time ratings
    Options