Engine Specifications
Aspiration
NA, T, TABore
4.13 inDisplacement
269 in³Engine Model
In-line 4, 4-Stroke-Cycle DieselGovernor Type
ElectronicStroke
5 in -
Generator Set Configurations
Emissions
NST -
Generator Set Dimensions
Height
39.4 inLength
68.9 inWeight
805 kg (1775 lb) - 1015 kg (2338 lb)Width
47.8 in -
Generator Set Specifications
Frequency
50 / 60Maximum Rating
99.0 ekW (123 kVA)Minimum Rating
36.0R ekW (45 kVA)Speed
1500 / 1800 rpm -
Generator Specifications
Excitation
Separately excited from auxiliary winding to provide 300% short circuit current up to 10 secondsIP Rating
IP23 water protection (IP44 available for certain models, contact your dealer for information)Insulation
Class HNumber of Leads
12 lead reconnectablePitch
2/3Voltage Regulator
Solid state voltage regulator with integral voltage adjustment potentiometer -
Power Rating
Power Range
36.0R - 99 ekW
Air Inlet System
- Air cleaner, single element canister type w/ service indicator and rain cap
- Dry insulated turbocharger (DIT and DITA models only)
- Glowplug cold start system
Cooling System
- Heat exchanger cooled packages w/ Cupro-nickel tube bundle (sized for 50 o C ambient air and 32 o C sea water) or Keel cooled packages (sized for 50 o C ambient air)
- De-aeration expansion tank
- Plate-type engine oil cooler
- Gear driven centrifugal jacket water pump
- Gear driven self priming sea water pump
- Caterpillar Extended Life Coolant (heat exchanger cooled packages)
Exhaust System
- Dry insulated turbocharger
- Water-cooled exhaust manifolds
Fuel System
- Primary fuel filter / water separator
- Secondary fuel filter (LH)
- Fuel priming pump electric
- Energize to run shutoff solenoid
Generator
- 12 lead reconnectable
- 3 phase all models
- Brushless
- IP23 water protection
- Connection poles
Lube System
- Lubricating oil
- Oil filter (LH)
- Dipstick (LH)
- Fumes disposal (closed system)
Mounting System
- Steel base frame with drip pan
- Anti-vibration mounts
Starting/Charging System
- Negative isolated ground electric system
General
- Single side service (LH)
- Keel cooled gensets do not include the keel cooler(s)
Space heater kit
- 240V AC, 120V AC