C32 ACERT generator sets incorporate a separate circuit aftercooling system (SCAC) for all configurations. The primary advantage of the SCAC systsem is reduced aftercooler corrosion since no sea water circulates through the aftercooler. Many other improvements on these engines contribute to minimizing owning and operating costs. The EPA Tier 3, IMO II, EU Stage IIIA compliant ratings are available with heat exchanger or keel cooled options. Heat exchanger configurations have an optional front mounted sea water pump.

Get a Quote

    Fabick Cat needs this information to contact you about our products and services. You may unsubscribe from communications at any time. For more information, please review our Privacy Policy.

    • Engine Specifications
      Aspiration
      Turbocharged and aftercooled
      Bore
      5.7 in
      Displacement
      1959 in³
      Engine Model
      Vee-12, 4-stroke-Cycle-Diesel
      Fuel System
      MEUI
      Governor Type
      Electronic
      Stroke
      6.38 in
    • Generator Set Dimensions
      Height
      65.6 in
      Length
      162.8 in/4271 mm (minimum), 175.3 in/4452 mm (maximum)
      Weight - Estimated
      15721 lb
      Width
      60.2 in
    • Generator Set Specifications
      Emissions/Fuel Strategy
      EPA Tier III
      Frequency
      60hz
      Maximum Rating
      940 ekW (1175 kVA)
      Minimum Rating
      730 ekW (913 kVA)
      Speed
      1800 rpm
    • Generator Specifications
      Excitation
      Permanent magnet
      IP Rating
      23
      Insulation
      Class H
      Number of Bearings
      2 roller bearings
      Number of Leads
      6
      Number of Poles
      4
      Voltage Regulator
      CDVR
    AIR INLET SYSTEM
    • Separate circuit after-cooled (SCAC)
    • Turbocharger, jacket water cooled
    • Turbocharger inlet, 152 mm (6 in) OD straight connection
    CONTROL SYSTEM
    • If an EMCP panel or MGCP option is not chosen as optional equipment, then start/stop controls must be provided by the customer
    • Electronic diagnostics and fault logging
    • Engine Protection Mode for extended ambient conditions
    • Electronic fuel/air ratio control
    COOLING SYSTEM
    • Separate Circuit After-Cooling (SCAC) for Heat Exchanged (HEX) & Keel cooled engines
    • Jacket Water (JW) and SCAC Heat Exchangers Shell & Tube for HEX cooled engines
    • SCAC pump, gear driven
    • Jacket water pump, gear driven
    • Sea water pump, bronze impeller, gear driven, for HEX cooled engines only
    • Jacket water HEX with Sea water pump Connections: 76.2 mm (3in) ID Standard
    • 4 Bolt ANSI Flange Connection
    • Jacket water HEX without Sea water pump Connection: 2.5" hose barb connection (inlet), 76.2 mm (3in) ID Standard 4 Bolt ANSI Flange (outlet)
    • Keel Connections: 76.2 mm (3in) ID Standard 4 Bolt ANSI Flange Connection
    • SCAC and JW shunt tanks for maintaining proper Pump inlet pressures
    EXHAUST SYSTEM
    • Water-cooled exhaust manifold & turbocharger
    • 4 Bolt 130 mm (5.12 in) diameter flanged outlet
    FLYWHEELS & FLYWHEEL HOUSINGS
    • Flywheel Housing, SAE No. 0
    • Flywheel, 18 inch, 136 teeth
    • SAE standard rotation
    FUEL SYSTEM
    • Duplex Fuel Filters, Spin-on, RH service
    • Fuel connections size: Supply JIC 37 Deg -10 (7/8-14), Return JIC 37 Deg -8 (3/4-16)
    • Plate-type fuel cooler installed behind Aftercooler Shunt Tank
    • Fuel transfer pump, gear driven
    • Manual fuel priming pump
    GENERATORS AND GENERATOR ATTACHMENTS
    • SR5 form wound
    • 2 roller bearings
    • Permanent magnet excitation
    • 4 pole, 6 leads, Series Star connected
    • Caterpillar's Digital Voltage Regulator (CDVR)
    • Marine Class H insulation, Class F temperature rise
    • Surface mounted platinum (PT100) 3-wire RTDs, 2 per phase on stator and one each on support bearings
    • Anti-condensation space heaters (2 elements - 240 VAC, 1000 Watts
    • IP23 Protection suitable for use with Fixed Water Based Local Application Fire Fighting Systems (FWBLAFFS)
    • System IV insulation for harsh environment protection
    LUBE SYSTEM
    • Simplex oil filters, RH service
    • Deep sump oil pan
    • RH service oil filler locations
    • RH service dipstick
    • Oil pump, gear driven
    MOUNTING SYSTEM
    • Formed C-channel rails, 300mm (11.81in) height
    • Six shipped loose combined helical spring/rubber
    • isolators for installation below package base
    GENERAL
    • Front Damper guard
    • Common electrical bondng point on HEX and KEEL cooled engines
    ALARM AND PROTECTION
    • Remote panels
    • MCS Controller
    • Power analyzer module
    • Oil level, exhaust temperature, air starting pressure, heat exchanger pressure sensors
    EXHAUST SYSTEM
    • Dry Elbows
    • Flexible Fitting
    • Flange
    • Muffler
    • Muffler Spark Arresting
    • Rain Cap
    AIR INLET SYSTEM
    • Air Inlet Cleaner
    • Closed Crankcase Ventilation
    • Air inlet adapter
    CHARGING SYSTEM
    • Battery Chargers, Charging Alternators
    CONTROL SYSTEM
    • Load Sharing Attachment
    FUEL SYSTEM
    • Water Separator
    LUBE SYSTEM
    • Duplex Oil Filters, Sump Pump
    PROTECTION SYSTEM
    • Fuel and Oil Shielding
    STARTING SYSTEM
    • Electric Starting Motors - Single 24 Volt
    • Air Starting Motor
    • Dual Starting Motors (Electric and Air)
    • Air Start Accessories
    • Starting Aids - JW Heaters
    • Battery Sets - 24 Volt - Dry