New CAT Equipment

C4.4 Generator Set

36 - 60 ekW Diesel Generator Set

Producing reliable power from 36 to 60 ekW at 60 Hz, our C4.4 diesel generator sets designed to ISO 8528-5 transient response requirements. All C4.4 generator sets meet EPA Stationary Emergency (Tier 3) emissions standards.

Get a Quote

    Fabick Cat needs this information to contact you about our products and services. You may unsubscribe from communications at any time. For more information, please review our Privacy Policy.

    Benefits

    Suitable for Harsh & Testing Environments

    Reliability tested for minimum 500 Hours

    Ensures you can count on emergency power when it is needed

    Optimised for 5% Lower Fuel Consumption

    Longer run times between fuel fills; reduced operating costs
    • Engine Specifications
      Aspiration
      Turbocharged
      Bore
      4.13 in
      Compression Ratio
      18.2:1
      Displacement
      268.5 in
      Engine Model
      C4.4, In-line 4, 4-cycle diesel
      Fuel System
      Electronic (adjustable)
      Governor Type
      AdemA4
      Stroke
      5 in
    • Generator Set Dimensions
      Height - Maximum
      53.6 in
      Length - Maximum
      75.8 in
      Width - Maximum
      44.1 in
    • Generator Set Specifications
      Duty Cycle
      Standby, Prime
      Emissions/Fuel Strategy
      U.S. EPA Cert., Tier 3
      Frequency
      60 Hz
      Maximum Rating
      60 ekW
      Minimum Rating
      36 ekW
      Speed
      1800 rpm
      Voltage
      208 to 600 Volts
    Certificates
    • IBC seismic and wind Certifications
    Charging System
    • NFPA battery charger UL10A 120VAC
    Air Inlet System
    • Air cleaner
    • Cartridge type air filter
    Circuit breakers
    • Second circuit breaker box
    • 3-Pole 100% rated
    • Power terminal strip
    • Breakers (100% UL rated)
    Control Panel
    • 1000028996
    Exhaust System
    • Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
    Fuel System
    • Standard open set fuel tank/base supplied base, formed steel with single wall integral 8-hour fuel tank
    Cooling System
    • Coolant drain line with valve
    • Radiator and cooling fan with guards
    • Fan drive, battery charging alternator drive
    • Caterpillar extended life coolant
    • Radiator stone guard
    Generator
    • 12 Leads
    Governing System
    • Mechanical and electrical governing system - model dependent
    Lube System
    • Oil drain line with valve
    • Lubricating oil
    Control Panels
    • WCA1 Low coolant temperature alarm
    • WSS1 Low coolant level shut down
    • FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected
    • NFPA110 bundle includes:
    • PAA1 Panel mounted audible alarm
    • A Coolant heater, remote annunciator or 0.8 power factor test may be required depending on the application
    • Oil temperature gauge and sender
    • PBC10NU NFPA battery charger
    • Ground fault relay
    • Discrete I/O module
    • Volt free contacts genset run and common alarm
    • Audible alarm
    • Remote E-stop button
    • Remote annunciator module
    • Low coolant temperature alarm
    • Protective devices:
    • Overload shutdown via breaker
    • Fuel level reading
    • Low coolant level shutdown
    General
    • Engine and alternator pre-paint, Caterpillar yellow
    Starting/Charging System
    • 24V battery with rack and cables
    • Batteries
    Certificates
    • IBC seismic and wind Certifications
    Alternator System
    • R Frame auxilliary winding
    Air Inlet System
    • Cartridge type air filter
    Charging System
    • NFPA battery charger UL10A 120VAC
    Circuit breakers
    • 3-Pole 100% rated
    • Breakers (100% UL rated)
    • Second circuit breaker box
    • Power terminal strip
    Control Panels
    • Discrete I/O module
    • Remote annunciator module
    • Remote E-stop button
    • Protective devices: Low coolant temperature alarm - Low coolant level shutdown - Fuel level reading - Overload shutdown via breaker
    • Ground fault relay
    • Audible alarm
    • Oil temperature gauge and sender
    • Volt free contacts genset run and common alarm
    • NFPA110 bundle includes: FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected - WSS1 Low coolant level shut down - WCA1 Low coolant temperature alarm - PAA1 Panel mounted audible alarm - PBC10NU NFPA battery charger - A Coolant heater ,remote annunciator or 0.8 power factor test may be required depending on the application
    Heating Elements
    • Coolant heater
    • Battery heater
    • Anti-condensation heater
    • Lube oil sump heater
    • Jacket water heater
    • Wiring for canopy space heater
    Cooling System
    • Radiator transition flange
    Enclosures
    • Panel viewing window
    • External emergency stop
    • Sound attenuated enclosure, Level 2
    • Weatherproof enclosure
    • Sound attenuated enclosure, Level 1
    Fuel System
    • 5 Gallon fill containment
    • Tank riser
    • 209 and 394 gallon sub-base fuel tanks
    • Emergency vent pipe
    • 5 Gallon spill containment
    Mounting System
    • Seismic vibration isolators
    Tests
    • Generator test report
    • PGS Test report @ 0.8 power factor
    • 4 Hour factory test
    • PGS Test report @ 1.0 power factor
    Exhaust System
    • 10, 25 and 35 dBA silencer systems
    • Overhead silencer mounting kit
    Generators
    • Permanent magnet excitation (PMG) generator