New CAT Equipment

C175-16 Generator Set

2500 - 3365 ekW Diesel Generator Set

Producing reliable power from 2500 - 3365 ekW at 60 Hz, our C175-16 diesel generator sets are made to meet your mission critical, continuous, standby and prime applications. We've designed each to ISO 8528-5 transient response requirements and to accept 100% rated load in one step. The generator set is Low Fuel Consumption, U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards) certified.

Get a Quote

Benefits

Over 20,000,000 Operating hours

at Global locations

Over 3000 units

In the field

Highest Rated Tier 4 Product

Available on the market

Learn more about the C175-16 Generator Set

Watch

  • Engine Specifications
    Aspiration
    Turbo Aftercooled
    Bore
    6.89 in
    Compression Ratio
    16.7:1
    Displacement
    6456.31 in³
    Engine Model
    C175-16 SCAC, V-16, 4-Stroke Water-Cooled Diesel
    Fuel System
    Common Rail
    Governor Type
    ADEM� A4
    Stroke
    8.66 in
  • Generator Set Dimensions
    Dry Weight - Genset (maximum)
    57774 lb
    Dry Weight - Genset (minimum)
    42750 lb
    Height - Maximum
    134.2 in
    Height - Minimum
    86.9 in
    Length - Maximum
    330.6 in
    Length - Minimum
    250.9 in
    Width - Maximum
    124.3 in
    Width - Minimum
    82.7 in
  • Generator Set Specifications
    Duty Cycle
    Standby, Mission Critical, Prime, Continuous
    Emissions/Fuel Strategy
    Low Fuel, Tier 2
    Frequency
    60 Hz
    Maximum Rating
    3365 ekW
    Minimum Rating
    2500 ekW
    Prime Power Rating
    3115(no fan)/3000/2825(no fan)/2725 ekW
    Speed
    1800 RPM
    Standby Rating
    3365(no fan)/3250/3100(no fan)/3000 ekW
    Voltage
    480 to 13800 Volts
Air Cleaner
  • Single element with service indicator
Starting
  • Dual electric starters
Cooling
  • Standard Ambient Radiator
Crankcase Ventilation System
  • Non filtered crankcase ventilation
Mounting System
  • Rails
Controller
  • Cat ECS 100
Telematics
  • Ethernet
Alternator
  • Form Wound
  • Permanent Magnet (PM) Excitation
Power Termination
  • Busbar
Air Cleaner
  • Dual element with service indicator
Starting
  • Standard batteries
  • Oversized batteries
  • Battery charger - 20A
  • Battery charger - 40A
  • Air starter(s)
  • Jacket water heater
Cooling
  • No Radiator
Muffler
  • Industrial grade (15 dB)
  • Critical grade (25 dB)
  • Hospital grade (35 dB)
Mounting System
  • Rubber
  • Spring vibration Isolators
  • Seismic rated vibration isolators
  • No Isolators
Controller
  • Cat ECS 200
  • EMCP 4.4
Controller attachments
  • Local annunciator module
  • Remote annuciator module
  • Expansion I/O module
  • Remote monitoring software
Telematics
  • Cellular
Extended service terms
  • 2 year (Prime)
  • 3 year
  • 5 year
  • 10 year
Extended service coverage
  • Silver
  • Gold
  • Platinum
  • Platinum plus
Alternator Temperature rise (over 40°C ambient)
  • 80°C
  • 105°C
  • 125°C/130°C
  • 150°C
Alternator Output Voltage
  • 480V
  • 600V
  • 4160V
  • 6300V
  • 6600V
  • 6900V
  • 12470V
  • 13200V
  • 13800V
Alternator attachments
  • Anti-condensation space heater
  • Stator and bearing temperature monitoring and protection
Power termination
  • Circuit breaker
Circuit breaker
  • 4000A
  • 5000A
  • IEC
  • UL
  • 3-pole
  • Electrically operated
Trip Unit
  • LSI
  • LSI-G
  • LSI-P
  • LSIG-P
Ancilliary Equipment
  • Automatic transfer switch (ATS)
  • Paralleling switchgear
  • Paralleling controls
Certifications
  • UL 2200 Listed
  • IBC seismic certification
  • HCAI/OSHPD OSP preapproved

Download Resources