New CAT Equipment

C13 Generator Set

320 - 400 ekW Diesel Generator Set

The C13 diesel generator sets have been developed for your mission critical, standby and prime applications. Producing reliable power from 320 to 400 ekW at 60 Hz, each generator set has been designed to meet ISO 8528-5 transient response requirements and built to accept 100 % rated load in one step. Our C13 generator sets are certified to Low Fuel Consumption Emissions / Fuel Strategy.

Get a Quote

    Fabick Cat needs this information to contact you about our products and services. You may unsubscribe from communications at any time. For more information, please review our Privacy Policy.

    Benefits

    Integrated Cat® Product Link Control System

    • Track Genset Health and Operation Parameters
    • Genset Utilization and Performance Tracking

    Remote Connectivity 24/7/365 Monitoring

    Cat Connect option ensures your generator set is always ready to start and perform as expected

    Optimised for 5% Lower Fuel Consumption

    Longer run times between fuel fills; reduced operating costs
    • Engine Specifications
      Aspiration
      Turbocharged Air to Air Aftercooled
      Bore
      5.12 in
      Compression Ratio
      16.3:1
      Displacement
      763 in³
      Engine Model
      C13 ACERT In-line 6, 4-cycle diesel
      Fuel System
      MEUI
      Governor Type
      AdemA4
      Stroke
      6.2 in
    • Generator Set Dimensions
      Height - Maximum
      84 in
      Length - Maximum
      186.7 in
      Width - Maximum
      79.3 in
    • Generator Set Specifications
      Duty Cycle
      Standby, Prime
      Emissions/Fuel Strategy
      EPA Stationary Emerg Use
      Frequency
      60 Hz
      Maximum Rating
      400 ekW
      Minimum Rating
      320 ekW
      Speed
      1800 rpm
      Voltage
      208 to 600 Volts
    Air Inlet System
    • Turbocharger
    • Aftercooler core
    • Air cleaner; light duty with disposable paper filter
    Starting / Charging
    • Charging alternator
    • 24 Volt electric starting motor
    Control Panel
    • GCCP 1.3
    Control System Controller
    • GCCP 1.3
    Cooling System
    • Fan drive, battery charging alternator drive
    • Caterpillar extended life coolant
    • Coolant drain line with valve
    • Radiator and cooling fan with guard
    Certification
    • EPA stationary emergency use
    Exhaust System
    • Stainless steel exhaust flex, gaskets, raincap & SAE exhaust flange for customer use - shipped loose
    Base / Fuel Tank
    • Audio and visual fuel alarm
    Fuel System
    • Standard open set fuel tank/base supplied
    • Base, formed steel with single wall integral 8-hour fuel tank
    Protection
    • Safety shutoff - Overspeed
    • Safety shutoff - Low oil pressure
    • Safety shutoff - High water temperature
    Generator and Attachments
    • Segregated low voltage (AC/DC) wiring panel
    • Power center, IP22
    • A Frame generator - IP21 Protection
    • Integrated voltage regulator (IVR)
    • Optional LC Frame generator - IP23 Protection
    • Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
    Governing System
    • Cat electronic governor (ADEM A4)
    Lube System
    • Oil cooler
    • Oil drain valves
    • Lubricating oil
    Mounting System
    • Includes lifting provisions and termination points for coolant and lube oil drain lines
    • Captive linear vibration isolators between base and engine-generator
    Starting / Charging System
    • 24V battery with rack and cables
    General
    • Engine and alternator pre-paint, Caterpillar yellow
    European Certificates
    • Global Certification for CIS
    • EU Certificate of Conformance (CE)
    Air Inlet System
    • Single element air cleaner
    • Dual element air cleaner
    Circuit breakers
    • Padlockable circuit breaker device
    • 3 Pole (IEC-100% rated) Circuit breaker
    • Shunt trip for IEC circuit breaker
    • 4 Pole (IEC-100% rated) Circuit breaker - Motorised
    • Circuit breaker (IEC) Auxiliary contacts
    • 4 Pole (IEC-100% rated) Circuit breaker
    • Power terminal strip
    • 3 Pole (IEC-100% rated) Circuit breakers - Motorised
    Control Panels
    • Control panel protective devices: Earth fault relay ; Earth leakage ground fault ; Overload shutdown via breaker ; Low fuel level alarm ; Low fuel level shutdown ; High fuel level alarm ; Fuel level sensor
    • GCCP 1.4
    • Volt free contacts
    • Local alarm modules: Local annunciator
    • Remote annunciator module
    Cooling System
    • Radiator duct flange
    • Stone guards
    • Low coolant temperature alarm
    Enclosures
    • Sound attenuated enclosures
    • High ambient sound attenuated enclosures
    Exhaust System
    • Flexible 8 inch exhaust fittings
    • Mufflers - End in/end out
    • 10, 25 and 35 dBA attenuation
    • 6 and 8 inch elbow kit
    • 6 and 8 inch flange GP
    Fuel System
    • Fuel transfer system controls
    • Manual fuel transfer pump
    • Integral dual wall fuel tank base
    Generator and Attachments
    • LC frame generator
    • LC CIP generator
    • Space heaters
    • Ingress protection
    • A Frame oversize generator
    • Permanent magnet excitation (PMG) generator
    • A Frame CIP generator
    Lube System
    • Manual sump pump
    Mounting System
    • Narrow skid base
    starting / Charging System
    • Battery disconnect switch
    • Jacket water heater
    • 5 Amp single Battery charger