When the job takes you into a hazardous location, Cat® HazPak engines are ready. Our complete range of services and engine packages cover both industry standards and your operation with maximum safety. Cat C18 ACERT HazPaks are hazardous location power units that are the ideal solution for specialized and demanding operations in the oilfield. Units are hazardous-location certified from the factory to minimize installation design, time, and cost. HazPaks are certified to operate in potentially explosive environments. Cat hazpaks are backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty. Cat C18 ACERT HazPak. Rating: 533 bkW (715 bhp) @ 2100 rpm.

Learn More About This Piece of Equipment

360° Views

Product Specs

Package Specifications

Minimum Rating
715BHP
Maximum Rating
715BHP
Peak Torque - Speed
2809 N•m (2072 lb-ft) @ 1500 rpm
Displacement
1106in³
Aspiration
Turbocharged-Aftercooled
Governor and Protection
Electronic ADEM™ A4
Weight - Net Dry - Approximate
8137lb
Oil Change Interval
250 hours
Rotation from Flywheel End
Counterclockwise
Flywheel and Flywheel Housing
SAE 0 or 1
Stroke
7.2in
Bore
5.7in
Flywheel Teeth
136 (SAE 0), 113 (SAE 1)
Emissions
IMO Tier II

Capacity for Liquids

Cooling System
124.5qt (US)
Lube Oil System - Refill
16.9qt (US)

Equipment

  • Air Inlet System
    • Dry-type two-element air filter with restriction indicator, separate circuit aftercooler with ATEX approved air shutoff valve, inlet flame arrestor
  • Control System
    • Industry-standard ADEM A4 control system; inlet air shutoff valve for integration with supervisory safety system; electronic governing, programmable ratings, automatic altitude compensation, power compensation for fuel temperature, electronic diagnost
  • Cooling System
    • Cooling package designed for 45°C ambient capability; separate cooling circuit for aftercooler; offshore-capable radiators for jacket water and aftercooler circuits are manufactured using steel fabrications, galvanized solder dipped cooling elements a
  • Exhaust System
    • Exhaust gas cooler, plenum, and outlet box assembly; ATEX compliant - designed to limit the exhaust gas and exhaust duct surface temperatures to T3 (200°C); exhaust gas flametraps suitable for Gas Group IIA; designed and tested in accordance with the
  • Flywheels And Flywheel Housing
    • SAE No. 1 cast iron housing; flywheel for SAE-1 housing, pilot bore for 100 mm diameter bearings; provides LH and RH starter bore location
  • Fuel System
    • Electronic unit injector, upward-angled fuel priming pump, primary filter and water separator, engine-mounted secondary fuel filter
  • General
    • Package ambient capability is -20°C to 45°C; mechanical systems are designed for gas group IIA, electrical systems are designed for gas group IIC, all systems meet temperature class T3 (200°C limit); includes a declaration of conformity for the entire
  • Lube System
    • Oil cooler, LH oil gauge

Optional Equipment

  • Air Compressor
    • Belt-driven, two-cylinder, single-stage, reciprocating with a rated displacement of 13.2 cfm at 1250 rpm compressor speed; includes two environmental drains
  • Charging System
    • 24V 35A EX d ATEX compliant alternator for Gas Group IIB, temperature class T3; heavy-duty, brushless. 24V 65A alternator, NEC 500 Class 1 Division 2 for Gas Groups C&D, temperature Class T3; heavy-duty, brushless. 24V 55Ah EX d e II T4 increased safe
  • Control System
    • Air, electric, or hydraulic shutdown system input options available
    • Throttle knob speed control - shipped loose if no control panel option selected; ATEX approved 24V operation; twist knob, locking design; 2-turns, low to high speed; CCW rotation to increase engine speed, push in or turn CW to return to low idle
    • Messenger display - shipped loose if no control panel option selected; electronic display unit for monitoring key engine operation data and diagnostic information on a full graphic LCD screen; four select buttons to scroll through the engine data and
    • PCS2 control board - provides supervisory safety system functionality and overspeed shutdown control; includes start button, run/stop switch, emergency stop button, mounting locations for throttle control and messenger display, userconfigurable alarm a
    • 3GP control panel - provides gas detection, supervisory safety system functionality, and overspeed shutdown control; allows operation without exhaust flame traps; includes start button, run/stop switch, emergency stop button, mounting locations for th
  • Fuel System
    • Fuel cooler, installed, maintains acceptable fuel temperature when running from day tank
  • Starting System
    • Air and hydraulic starters available