The C32 with the upgradeable packaging design has been developed for a wide range of applications, from emergency standby installations such as healthcare and datacenters to continuously powering remote installations. The packages can be optimized for performance to matters to you with either low emissions or low fuel consumption versions available. Backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty, Cat generator sets will provide the reliability and durability you expect.

Product Specs

Engine Specifications

Stroke
162 mm (6.38 in)
Displacement
32.1 L (1958.86 in3)
Engine Model
C32 TA, V-12, 4-Stroke Water-Cooled Diesel
Air Inlet
Single element canister style with service indicator
Exhaust Flange Size - Internal Diameter
203.2 mm (8.0 in)
Fuel System
MEUI
Governor Type
Adem™A4
Aspiration
TA
Compression Ratio
15.0:1
Bore
145 mm (5.71 in)

Generator Set Configurations

Emissions/Fuel Strategy
Low Fuel Consumption, Low Emissions

Generator Set Specifications

Speed
1800 RPM
Frequency
60 Hz
Voltage
220 to 4160
Maximum Rating
1000 ekW (1250 kVA)
Minimum Rating
830 ekW (910 kVA)

Equipment

  • Air Inlet System
    • Air Cleaner; single element canister type with service indicator
  • Control System
    • EMCP 4 controls including:
    • Run / Auto / Stop Control
    • Speed adjust
    • Voltage adjust
    • Engine cycle crank
    • Emergency stop pushbutton
    • EMCP 4.2 controller features:
    • 24-volt DC operation
    • Environmental sealed front face
    • Text alarm/event descriptions
    • True RMS AC metering, 3-phase, �1% accuracy
    • Digital indication for:
    • RPM
    • DC volts
    • Operating hours
    • Oil pressure (psi, kPa or bar)
    • Coolant temperature
    • Volts (L-L & L-N)
    • Frequency (Hz)
    • Amps (per phase & average)
    • Power Factor (per phase & average)
    • kW (per phase, average & percent)
    • kVA (per phase, average & percent)
    • kVAr (per phase, average & percent)
    • kW-hr (total)
    • kVAr-hr (total)
    • Warning/shutdown with common LED indication of shutdowns for:
    • Low oil pressure
    • High coolant temperature
    • Overspeed
    • Emergency stop
    • Failure to start (overcrank)
    • Low coolant temperature
    • Low coolant level
    • Programmable protective relaying functions:
    • Generator phase sequence
    • Over/Under voltage (27/59)
    • Over/Under Frequency (81 o/u)
    • Reverse Power (kW) (32)
    • Reverse Reactive Power (kVAr) (32RV)
    • Overcurrent (50/51)
    • Communications:
    • Customer data link (Modbus RTU)
    • Accessory module data link
    • Serial annunciator module data link
    • 6 programmable digital inputs
    • 4 programmable relay outputs (Form A)
    • 2 programmable relay outputs (Form C)
    • 2 programmable digital outputs
    • Compatible with the following optional modules:
    • Digital I/O module
    • Local Annunciator
    • Remote CAN annunciator
    • Remote serial annunciator
    • RTD module
    • Thermocouple module
  • Cooling System
    • Radiator fan and fan drive
    • Fan and belt guards
    • Coolant drain line with valve
    • Low coolant level sensor
    • Caterpillar Extended Life Coolant
  • Exhaust System
    • Exhaust manifold - dry - single - 8 in
    • 203 mm (8in) ID round glanged outlet
  • Fuel System
    • Primary fuel filter with water separator
    • Secondary fuel filters
    • Fuel cooler
    • Fuel priming pump
  • Generators And Attachments
    • 3 phase brushless, salient pole
    • Integrated Voltage Regulator (IVR) - IVR includes reactive droop capability, 3 phase voltage sensing, PF control, maximum excitation limiter and line-loss compensation
    • 6 Lead
    • Winding temperature detectors
    • Low Voltage:
    • Random wound
    • Internal Excitation
    • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime/150C standby)
    • Reactive droop
    • Bus bar connections, top center mounted, top cable entry
    • 60 Hz models: NEMA standard hole pattern
    • Medium Voltage:
    • Form Wound
    • Permanent Magnet
    • Winding temperature detectors
    • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime/150C standby)
    • Bus bar connections, right side extension box, bottom cable entry
    • 60 Hz models: NEMA standard hole pattern
  • Governing System
    • ADEM(tm) A4
  • Literature
    • English
  • Lube System
    • Lubricating oil
    • Gear type lube oil pump
    • Integral lube oil cooler
    • Oil filter, filler and dipstick
    • Oil drain lines and valve
    • Fumes disposal
  • Mounting System
    • Rails - Engine / generator / radiator mounting
    • Rubber anti-vibration mounts (shipped loose)
  • Starting / Charging System
    • 24-volt electric starting motor
    • 45 amp charging alternator
    • Battery, rack and cables
    • Battery disconnect switch
  • General
    • Paint: Caterpillar yellow with high gloss black rails & radiator
    • Right hand servicing
    • Flywheel and flywheel housing-SAE No. 0 with SAE No. 0 to 00 adapter
    • SAE Standard Rotation

Optional Equipment

  • Control System
    • EMCP (4.2) (4.3) (4.4)
    • Remote monitoring software
    • Local annunciator module
    • Local annunciator module
    • Governors
    • Remote annunciator module
    • Auxiliary box
    • EMCP (4.2) (4.3) (4.4)
    • Customer interface options
    • Expansion I/O module
    • Generator temperature monitoring
  • Engine Options
    • Rubber anti-vibration mounts (90% efficient)
    • Spring type anti-vibration mounts (95% efficient)
    • Radiator duct flange
    • Dual element air cleaners
    • Heavy duty electric starting motors
    • Jacket water heater
    • Muffler (industrial grade)
    • Battery Charger (10A)
    • Exhaust guards / shields
    • Heavy Duty Batteries
    • Heavy duty air cleaners
  • Control Panel Options
    • Panel lights
    • Remote speet adjust
    • Vandal proof door
    • Local PC monitoring
    • Auxiliary panel mounting locations
  • Cooling System
    • Standard radiator
    • Extended life coolant
    • Radiator duct flange
  • Enclosures
    • Sound attenuated enclosures
    • Premium sound attenuated enclosures
  • Extended Service Contract
    • 2 Year Extended Service Contract (ESC)
    • 5 Year Extended Service Contract (ESC)
    • 3 Year Extended Service Contract (ESC)
  • Premium Enclosures
    • Colors - Yellow, White, Beige, Grey
    • Premium enclosure fuel tank options
    • Cold weather bundle - AC Panel, outlests, lights, heater motorized louvers, installed battery charger, heavy duty batteries, dual starters, jacket water heater, generator space heaters
    • Fixed louvers - standard
    • Motorized louvers
    • DC lighting package
    • AC Panel, outlests and lights
    • Panel bracket
  • Generators
    • Excitation: [ ] Permanent Magnet Excited (PM) [ ] Internally Excited (IE)
    • Generator stator and bearing temperature monitoring & protection
    • Anti-condensation heaters
    • Temperature Rise over 40°C ambient: [ ] 150°C [ ] 125°C [ ] 105°C [ ] 80°C
    • Winding: [ ] Random [ ] Random with coastal insulation [ ] Form
  • Power Termination
    • Circuit breaker, IEC listed (fully rated)
    • Bus bars
    • Circuit breaker, 100% Rated, UL Listed (fully rated)
  • Exhaust System
    • Guard and shield system
    • Elbows
    • Flanges
    • Flexible fittings
    • Flange and exhaust expanders
    • Mufflers
    • Muffler installation kits
  • Factory Support
    • Factory commissioning
  • Generators And Attachments
    • Optional generators 1800 rpm; 220, 240, 380, 400, 480, 600 Volt @ 60 Hz 3 phase
    • Medium voltage optional generators 1800 rpm; 2400, 4160 Volt @ 60 Hz 3 phase
    • Space heater
    • Standard base
    • Long base
  • Lube System
    • Oil level regulator
    • 186 liter oil pan
    • Prelube pumps
  • Mounting System
    • Standard package isolators
    • Radiator isolators
    • Spring type vibration isolator
  • Special Tests / Reports
    • CSA test and certification
    • Neutral grounding connection
    • PGS test report @ 1.0 power factor
    • PGS test report @ 0.8 power factor
    • Generator test report
    • Standard genset TVA report
  • Extended Service Coverage
    • Customes must select one of the following Extended Service Coverage options
    • Platinum
    • Silver
    • Gold

Interested In This Product?

Call Fabick
1 (800) 845-9188

Dial Your Nearest Location:

800-845-9188
Fabick MO & IL
414-461-9100
Fabick WI & MI
View All Locations