3412C Generator Set

3412C Diesel Generator Sets

3412C Generator Set

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Learn More About This Piece of Equipment

360° Views

Product Specs

Engine Specifications

Stroke
6in
Displacement
1648.86in³
Bore
5.4in
Fuel System
Pump and Lines
Engine Model
3412C TA, V-12, 4-Stroke Water-Cooled Diesel
Compression Ratio
13:0:1
Governor Type
ADEM™ A5
Aspiration
TA

Generator Set Specifications

Minimum Rating
680 kVA
Maximum Rating
900 kVA
Voltage
208 to 600 Volts
Frequency
50 Hz
Speed
1500 RPM

Generator Set Configurations

Emissions/Fuel Strategy
Low Fuel Consumption

Equipment

  • Air Inlet System
    • Air cleaner, single element canister type with service indicator
  • Control Panel
    • EMCP 4.2B Genset Controller
    • Run / Auto / Stop Control
    • Speed Adjust
    • Voltage Adjust
    • Engine Cycle Crank
    • Emergency stop pushbutton
    • EMCP 4.2 B controller features
    • - 24-volt DC operation
    • - Environmental sealed front face
    • - Text alarm/event descriptions
    • Digital indication for:
    • - RPM
    • - DC volts
    • - Operating hours
    • - Oil pressure (psi, kPa or bar)
    • - Coolant temperature
    • - Volts (L-L & L-N)
    • Frequency (Hz)
    • - Amps (per phase & average)
    • - Power Factor (per phase & average)
    • - kW (per phase, average & percent)
    • - kVA (per phase, average & percent)
    • - kVAr (per phase, average & percent)
    • - kW-hr (total)
    • Warning/shutdown with common LED indication of shutdowns for:
    • Low oil pressure
    • - High coolant temperature
    • - Overspeed
    • - Emergency stop
    • - Failure to start (overcrank)
    • - Low coolant temperature
    • - Low coolant level
    • Programmable protective relaying functions:
    • - Generator phase sequence
    • - Over/Under voltage (27/59)
    • - Over/Under Frequency (81 o/u)
    • - Reverse Power (kW) (32)
    • - Reverse Reactive Power (kVAr) (32RV)
    • - Overcurrent (50/51)
    • Communications
    • - Customer data link (Modbus RTU)
    • - Accessory module data link
    • - Serial annunciator module data link
    • - 6 programmable digital inputs
    • - 4 programmable relay outputs (Form A)
    • - 2 programmable relay outputs (Form C)
    • - 2 programmable digital outputs
    • Compatible with the following optional modules:
    • - Digital I/O module
    • - Local Annunciator
    • - Remote CAN annunciator
    • - Remote serial annunciator
    • - Generator temperature monitoring module
  • Cooling
    • Radiator with guard (Sized for 50 degrees C)
    • Coolant drain line with valve, piped to edge of base
    • Fan and belt guards
    • Caterpillar Extended Life Coolant
    • Coolant level shutdown
  • Exhaust System
    • Stainless steel exhaust flex with ANSI style outlet flange, gasket, bolts and mating weld flange, shipped loose
  • Fuel System
    • Primary and secondary fuel filters
    • Fuel priming pump
    • Flexible fuel lines terminated on base
    • Water seperator
  • Generator And Attachments
    • SR4B self excited
    • Class H insulation
    • Class F temerature rise
    • 12 lead
    • VR6 Voltage Regulator
    • 3-phase sensing
    • 2:1 Volts/Hz
    • Reactive droop
    • Bus bar termination
  • Governing System
    • Cat electronic governor
  • Lube System
    • Lubricating oil
    • Oil filter
    • Oil drain line with valve, piped to edge of base
    • Fumes disposal, piped to front of radiator
  • Mounting System
    • Base, formed steel with linear vibration isolators between base and engine-generator
  • Starting / Charging System
    • 45 amp charging alternator
    • Fuel shutoff solenoid
    • 24 volt starting motor
    • Battery with rack, cables

Optional Equipment

  • Air Inlet System
    • Duel element air cleaners
    • Heavy duty air cleaners
    • Open element air cleaners
  • Circuit Breakers
    • 1250, 1600 Amp, 3 pole, IEC 100% rated, 24 volt DC shunt trip
    • 1600 Amp, 3 pole, Non-UL, 100% rated, 24 volt DC shunt trip
  • Control Panels
    • EMCP 4.3
    • EMCP 4.4
    • Vandal proof panel door
    • Common alarm / shutdown relay
    • Generator running VFC
    • Generator temperature monitoring package
    • Ground fault relay
    • First local annunicators
    • Remote custom annunicators
    • Local discrete I/O package
  • Cooling System
    • Radiator duct flange
    • Jacket water heaters
  • European Certifications
    • Eurasian conformity (EAC) mark
  • Exhaust
    • Mufflers
    • Elbow kit
    • Through wall installation kit
    • Manifold and turbocharger guard
  • Generator And Attachments
    • Permanent magnet excitation
    • Digital voltage regulator
    • Space heater
    • Oversize and premium generators
  • Lube System
    • Manual sump pump
  • Mounting
    • Fuel tank base (1200 ltr)
  • Special Tests / Reports
    • PGS test report @ 1.0 power factor
    • PGS test report @ 0.8 power factor
  • Starting / Charging
    • Battery chargers
    • Oversize batteries
    • Battery disconnect switch
    • Heavy-duty starting system
  • Governing System
    • Electronic load share

Interested In This Product?

Call Fabick
1 (800) 845-9188

Dial Your Nearest Location:

800-845-9188
Fabick MO & IL
414-461-9100
Fabick WI & MI
View All Locations