New CAT Equipment

D300 GC (60 Hz) Generator Set

300 ekW Diesel Generator Set

Producing reliable power of 300 ekW at 60 Hz, our D300 GC diesel generator set are designed to ISO 8528-5 transient response requirements. The D300 GC generator sets are engineered to EPA Stationary Emergency (Tier 3) emissions standards.

Get a Quote

    Fabick Cat needs this information to contact you about our products and services. You may unsubscribe from communications at any time. For more information, please review our Privacy Policy.

    Benefits

    Saves up to 31% Installed Space

    Requires less space for installation; leaves more room for your on-going operations

    Weighs up to 26% Less

    Easier handling; less structural reinforcement required to support genset weight

    Standard 105°C Alternator Temperature Rise

    Meets most all specifications; ensures long alternator life
    • Engine Specifications
      Aspiration
      Turbocharged Air-to-Air Aftercooled
      Bore
      4.4 in
      Compression Ratio
      16.3:1
      Displacement
      538 in³
      Engine Model
      Cat® C9 In-line 6, 4-cycle diesel
      Fuel System
      HEUI
      Governor Type
      AdemA4
      Stroke
      5.9 in
    • Generator Set Dimensions
      Dry Weight - Genset (maximum)
      6929.1 lb
      Dry Weight - Genset (minimum)
      5518.2 lb
      Height - Maximum
      86.7 in
      Height - Minimum
      67.2 in
      Length - Maximum
      155.5 in
      Width - Maximum
      56.7 in
      Width - Minimum
      56.3 in
    • Generator Set Specifications
      Duty Cycle
      Standby
      Emissions/Fuel Strategy
      EPA Stationary Emergency
      Frequency
      60 Hz
      Maximum Rating
      300 ekW
      Minimum Rating
      300 ekW
      Speed
      1800 rpm
      Voltage
      208 to 600 Volts
    Air Inlet System
    • Aftercooler core
    • Turbocharger
    • Air cleaner - Non canister, disposable
    Control Panel
    • GCCP 1.2
    Cooling System
    • Jacket water pump, gear driven, centrifugal
    • Thermostats and housing
    • Coolant drain valve
    • Radiator sight gauge
    • Blower fan and fan drive with guards
    • Radiator, package mounted
    Exhaust System
    • Exhaust manifold - dry
    Fuel System
    • Integral tank base, 24 hours, UL142
    • Fuel priming pump
    • Engine fuel transfer pump
    • Primary fuel filter w/integral water separator and secondary filter, spin on
    Generator Set
    • Complete system designed & built at ISO 9001:2000 certified facilities
    • All protective devices and control functions simulated and checked
    • Factory tested to design specifications at full load conditions
    Generators and Generator Attachments
    • IP23 Protection
    • 12 Leads
    • Insulation system, Class H
    • Standard winding protection for non-harsh environments with relative humidity ? 95%
    • Voltage regulator (single phase sensing)
    • Easy access to AVR and terminals
    • Terminal box, IP22 RHS facing, bottom cable entry
    • Brushless, self-excited 2/3 pitch (600V uses Internal excitation (IE))
    Governing System
    • Cat electronic governor (ADEM A4)
    Lube System
    • Shallow oil pan
    • Oil cooler
    • Fumes disposal to front of radiator
    • Oil drain with valve
    • Oil filler and dipstick
    • Oil filter, spin on
    • Lubricating oil, CK-4 (10W-30)
    Mounting System
    • Captive linear vibration isolators between base and engine-generator
    • Includes lifting provisions and termination points for coolant and lube oil drain lines
    Protection
    • Safety shutoff - High water temperature
    • Safety shutoff - Low oil pressure
    • Safety shutoff - Overspeed
    Starting/Charging System
    • 24-volt electric starting motor
    • 24V, 45 Amp Charging alternator
    General
    • Lifting eyes
    • Vibration damper
    • Parts book
    Air Inlet System
    • Air cleaner (Non canister disposable)
    Bases, Mounting & Fuel Tanks
    • Integral tank base, 24 hours, UL142
    • Audio & visual fuel alarm (@90% fuel level)
    • Wide Base - Skid
    • Fuel tank pill pipe & lockable cap
    Circuit breaker
    • 400A LSI
    • 600A LSI
    • 1200A LSI
    • 800A LS/I
    • Auxiliary contacts
    • 600A LS/I
    • 1200A LS/I
    • 400A LS/I
    • 800A LSI
    Control System
    • Audible alarm Gp
    • 16 -light NFPA 99/110 Annunciator
    • Twist release, Red button emergency stop
    • Ground fault relay
    • 100A Load center
    • Product link remote monitoring hardware
    • 20A GFCI (Ground Fault Circuit Interrupter)
    • Volt free contacts
    Enclosures
    • Sound attenuated Level 2 enclosure (White)
    • AC & DC Source lights
    • E-Stop
    Exhaust System
    • 6" Muffler - 25 dBA attenuation
    • Manifold and turbocharger guards
    • Flexible exhaust connection
    Generator
    • Space heater
    • Permanent magnet excitation (PMG) generator
    Starting System
    • Battery charger (UL Certified)
    • Jacket water heater
    • Standard battery set: 1000 CCA, 90 amp/hr.
    General
    • CSA Certification
    • Extended Service Coverage
    • UL2200 Certification
    • Generator test report